EFFECT OF SUCTIONING WITH NORMAL SALINE INSTILLATION INTO EDNOTRACHEL TUBE ON ARTERIAL BLOOD GAS EXCHANGE. IJN. 2001; 14 (28) :39-46
URL: http://ijn.iums.ac.ir/article-1-277-en.html

Abstract:   (6897 Views)

  Background : Disorder in diffusion of blood gases almost always is clue to collection of secretion in respiratory airways. So protecting the airway, correct suctioning to remove the secretion and maintenance of air way potency are necessary interventions in patient with end tracheal tube .

  Objective : To determine and compaire arterial blood gas in patient with open heart surgery with and without use of normal saline in suctioning end tracheal tube.

  Design : The study was a single group clinical trial. The end tracheal tube of each subject were suctioned once with normal saline and once without it. The arterial blood gases were compaired before and after each suctioning.

  Samples : 40 patient with open heart surgery were selected according to research purpose.

  Results : Instillation of normal saline bolus prior to end tracheal tube suctioning has an adverse effect on oxygen saturation (p=0.01) but it's effect on pao2 and paco2 was not significant.

  Conclusion : Use of normal saline in suctioning of end tracheal tube may cause disorder in gas exchange and tissue oxygenation. It is recommended that normal saline be used in low dose and only when there is a need for stimulation of cough reflex.

Full-Text [PDF 167 kb]   (1597 Downloads)    
Type of Study: Research | Subject: nursing
Received: 2007/11/27

© 2015 All Rights Reserved | Iran Journal of Nursing

Designed & Developed by : Yektaweb